- Contact Person : Ms. luo betty
- Company Name : Wuhan Wanpeng Science & Technology Co., Ltd.
- Tel : 86-27-83496953
- Fax : 86-27-83496752
- Address : Hubei,Wuhan,No.21 Jiefang Avenue Qiaokou Dist.,
- Country/Region : China
- Zip : 430035
5A-60A CMseries solar system PWM charge controller
Installation
Install
1. Ready tools and cables. Encourage you to matching the right cables. Ensure that the current density is less than 4mm² that is conductive to reducing the line voltage drop. Recommended: 30A with 10mm² cable. Check weather the installation sites compliance with the relevant safety requirements. Please avoid the damp, dusty, there is a place flammable, explosive and corrosive gases use the controller to install.
2. Install the controller into a fixed vertical plane. See section 5 of the pore size and pore spacing. In order to ensure a good thermal control conditions, please set aside each 10cm below the controller space.
3. As shown on the right, connect the (1) Load, (2) Battery and (3) Solar Panel to the controller according to the order of (1) (2) (3). Pay attention to the load, battery, solar panel and controller of same polarity.
4. Put into the external temperature sensor on the left of the controller (probe port). The temperature sensor should be similar space with battery. (Otherwise, the controller will control the parameters of all wrong temperature compensation.)
5. If you have remote monitoring and control function, please insert one end of the included communication wire on the right of the controller (communication port), the other end to connect to the host computer.
Demolition: To prevent accidents, please order the demolition of solar panels, battery and load disconnect with controller.
Note:Battery polarity will not damage the controller, but you will have a load equipm
Technical Data
Data Model | CM3024Z | CM3024Z | CM3048 | CM3048 | Data Model | CM3024Z | CM3048 |
Rated Current | 20A | 30A | 20A | 30A | Installation cable area. | ≤7# AWG (16mm2) | |
Rated Voltage | 12V/24V | 48V | Operating Temperature | -10°C~60°C | |||
Open Circuit Voltage of solar panel | ≤50V | ≤100V | Storage temperature | -30°C~70°C | |||
Low Voltage Disconnection(LVD) | 10.7V/21.4V | 42.8V | Humidity requirements | ≤90%,no condensation | |||
Float Voltage | 13.8V/27.6V | 55.2V | Size | 90 mm×188 mm×48 mm | |||
Low Voltage Reconnection(LVR) | 12.5V/25.0V | 50.0V | Mounting hole spacing | 60 mm×178 mm --Φ5 | |||
No load loss | ≤30mA | weight | 360g | ||||
Loop Voltage Drop | ≤170mV | Notes | Model suffix “Z” represent automatic identify system voltage level, “T” represent controller with remote monitoring. | ||||
Charging Mode | PWM mode | ||||||
Temperature Compensation | -4mV/Cell/°C |
5A-60A CMseries solar system PWM charge controller